Fans – Dell PowerEdge 1900 User Manual
Page 52

52
Installing System Components
3 Connect the power cables to the following components where applicable (see Figure 6-2 for connector
locations):
•
PWR1 connector on the system board
•
PWR2 connector on the system board
•
PWR CTRL connector on the system board
•
Hard drives
•
Diskette drive
•
Optical drive
•
Tape backup unit
•
Cable retention clips on the chassis (see Figure 3-4)
4 Replace the center fan bracket. See "Replacing the Center Fan Bracket" on page 79.
5 Replace the expansion-bay and processor fans (FAN1, FAN2, and FAN3). See "Removing and Installing
6 Close the system. See "Closing the System" on page 48.
7 Connect the power cable to the power supply and the power outlet.
Fans
The system contains six hot-plug cooling fans:
•
One expansion-bay cooling fan (FAN1)
•
Two processor cooling fans, one for each processor (FAN2 and FAN3)
•
Three memory module cooling fans:
–
One fan on top of the memory cooling shroud (FAN4)
–
Two fans at the rear of the system (FAN5 and FAN6)
NOTICE:
In the event of a problem with a particular fan, the fan’s number is referenced by the systems
management software, allowing you to easily identify and replace the proper fan.