Diskette drive

n

seek

failure

Incorrect configuration settings in the
System Setup program.

Run the System Setup program to
correct the settings. See "Using the
System Setup Program" on page 33.

Faulty or improperly installed diskette
drive.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 112.

Loose diskette drive interface cable, or
loose power cable.

Reseat diskette drive interface cable, or
power cable. See "Troubleshooting a
Diskette Drive" on page 112.

Diskette read failure

Faulty or improperly inserted diskette. Replace the diskette. If the problem

persists, see "Troubleshooting a Diskette
Drive" on page 112.

Diskette subsystem reset

failed

Faulty or improperly installed
diskette.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 112.

Drive not ready

Diskette missing from or improperly
inserted in diskette drive.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 112.

Error: Incorrect memory

configuration. DIMMs must

be installed in pairs of

matched memory size,

speed, and technology.

Mismatched or unmatched DIMMs
installed; faulty or improperly seated
memory module(s).

Ensure that all pairs of memory modules
are of the same type and size and that
they are properly installed. See
"Memory" on page 80. If the problem
persists, see "Troubleshooting System
Memory" on page 110.

Error: Memory failure

detected. Memory size

reduced. Replace the

faulty DIMM as soon as

possible.

Faulty or improperly seated memory
module(s).

See "Troubleshooting System Memory"
on page 110.

!!*** Error: Remote Access

Controller initialization

failure*** RAC virtual USB

devices may not be

available...

Remote Access Controller
initialization failure

Ensure that the Remote Access
Controller is properly installed. See
"Installing a RAC Card" on page 85.

FBD training error: The

following branch has been

disabled: Branch x

The specified branch (channel pair)
contains DIMMs that are
incompatible with each other.

Ensure that only Dell-qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com or your Dell sales agent to
ensure compatibility.

Table 1-5.

System Messages (continued)

Message

Causes

Corrective Actions