Autoloader environmental specifications – Dell PowerVault 124T User Manual
Page 72

Technical Specifications: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
file:///T|/htdocs/stor-sys/124T/en/124tvs16/specs.html[12/5/2012 10:26:14 AM]
Interface
LVD ultra wide SCSI-2, 16-bit wide, 68-pin HD connector
Initialize element
status
90 seconds (typical)
Typical cycle time < 40 seconds. One cycle consists of moving a cartridge from the tape drive to a magazine slot, selecting
another magazine slot, and then moving the cartridge back to the tape drive. It does not include the
time that the tape drive takes to unload or load/calibrate.
Average load time
(after placing
cartridge in drive)
VS1 = 120 seconds (to BOT for previously written tape)
Average unload
time (from BOT)
VS1 = 25 seconds (from BOT)
Autoloader Environmental Specifications
Characteristic
Specification
Temperature Range (Dry Bulb)
Operating
+10º to +35ºC
Nonoperating
–40º to +65ºC
Temperature Variation
Operating
10ºC per hour
Nonoperating
20ºC per hour
Humidity
Operating
20% to 80% noncondensing
Nonoperating
10% to 90% noncondensing
Gradient
10% per hour without condensation
Wet Bulb
Operating
26ºC maximum