Dell PowerVault 124T User Manual
Page 13

Installing the Autoloader: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
file:///T|/htdocs/stor-sys/124T/en/124tvs16/install.html[12/5/2012 10:25:55 AM]
8. When the scan is complete, verify the LUN device has been detected using the list storage adapters command.
Typical output with both the tape drive and loader being recognized:
0x08 [V321 -A3] Adaptec SCSI Card 39160/3960D – Ultra160 SCSI [slot 201]
0x16 [V321 -A3-D5:1] DELL PV-124T 0031
0x15 [V321 -A3-D5:0] CERTANCE ULTRIUM 2 1775
0x09 [V321 -A4] Adaptec SCSI Card 39160/3960D – Ultra160 SCSI [slot 202]
Netware may display unbound device, meaning a driver is not bound to the loader unless a driver from a backup
software is loaded. This does not prevent the backup application from detecting the LUN and binding the appropriate
driver.
NOTE: The user must type the command scan all upon OS boot every time. If backup software services automatically
start on OS boot, the user must disable them, run the scan all command, and re-enable the services.
NOTE: Netware may display unbound device meaning a driver is not bound to the loader unless a driver from a
backup software is loaded. This does not prevent the backup application from detecting the LUN and binding the
appropriate driver.