Dell PowerVault DR2000v User Manual
Page 31

ID
Issue
Description
Workaround/Solution
16247
scatter_repl_io
time out experienced
during replication.
During replication,
the system showed a
scatter_repl_i
o error.
Corrected the issue in the replication code.
16426
After upgrade from 1.
x
to 2.
x
, the GUI prompted
for reboot but reboot
did not occur on the
first try.
When upgrading
from 1.
x
to 2.
x
from
the UI, the reboot
does not appear to
reboot the system.
Before clicking the reboot button in the UI,
refresh the browser and to resolve the issue.
You can also do the upgrade from the CLI if
you wish to work around this issue.
16083
Dell DR4100 system
comes up in an error
state due to additional
power supply sensors
that are discovered
with newer iDRAC
firmware.
This was caused by a
new version of the
iDRAC firmware
which discovered
additional sensors.
Corrected the issue in the Hardware Monitor
code.
15795
There is no message
instructing user to
upgrade the Client OST
plugin when DR4X00
FW is upgraded.
Added messaging to
the UI so that during
the upgrade the user
is told to also
upgrade the OST
plugin if OST is being
used.
Added messaging to inform the user to
upgrade the plug also.
15695
GUI "Usage" page
doesn't show any stats
graphs in a special
case.
If the client machine
and the DR are not in
the same time zone,
then the usage
graphs may not show
the stats for some
period.
We now use the time zone of the server
rather than the client running the browser.
15275
Windows OST plug-in
install fails on a DC.
Installing the OST
plug-in on a DC fails.
The code now supports this option.
15067
Handle the ‘.’ as part of
the NETBIOS name.
Domain join to the AD
domain controller is
ok but access to
DR4000 share fails.
Handle/allow '.' in
NETBIOS name.
Access from
windows client using
test.com
\administrator.
smb.conf:
workgroup =
TEST.COM realm
= ad.test.com
Corrected the code path to allow '.' for
domain login groups.
31