12595

Our GUI allows a seven-character password;
however, the RDA with OST requires an eight-
character password.

If you want the RDA with OST user and GUI passwords to
match, then use an eight-character password as required
for the RDA with OST user.

9433

Global hot spare is not automatically
configured after replacing the GHS drive in
slot 0.

If the global hot spare is replaced, run maintenance by
using the --make_standby command to make the drive
a global hot spare. Contact Dell Technical Support for this
action.

Known Issues and Their Resolutions

The following table lists known issues and the related resolutions for this DR Series system release.

ID

Issue

Resolution

22168

RDCIFS was listed as supported on
Windows 2003 in the

Dell DR Series

System Interoperability Guide

, but this is

inaccurate. Windows 2003 does not
support the command set required to
support RDCIFS.

Updated the

Dell DR Series System

Interoperability Guide

for 3.1.2 to reflect

the correct support of RDCIFS.

22145

RDS OpDup was failing across the
firewall as the TCP connection timed out
during extended idle times. In this
release, we have added keep alive on the
RDS OpDup path connection.

Corrected in version 3.1.2.

21748

DR2000v FS was failing during boot on
some legacy Intel and AMD processors.

Corrected in version 3.1.2.

20766

DR Series deployment using a static IP
may come up in maintenance mode
during initial boot as default IP is not
being assigned.

Corrected in version 3.1.2.

Resolutions For Earlier Releases

The following table lists known issues, descriptions, and related solutions or workarounds for the DR Series system 3.1
release and earlier releases.

ID

Issue

Description

Workaround/Solution

21893

Bash Security Fix -
BASH Remote Code
Execution Vulnerability
(ShellShock).

Corrected in version 3.1.1.

21873

During an upgrade from
2.x to 3.x under some
unusual corner cases,
the latest configuration

Corrected in version 3.1.1.