About Your System
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 170 or
"Troubleshooting a Hard
Drive" on page 181 for the
appropriate drive(s) installed
in your system.
Shutdown failure
General system error.
See "Getting Help" on
page 199.
Sparing mode
disabled. For
sparing mode,
matched sets
of three must
be populated
across slots.
The memory configuration
does not match the setting
in BIOS. The BIOS setting
has been disabled.
Reconfigure the memory
modules for Memory
Sparing mode. See "System
Memory" on page 114.
The amount of
system memory has
changed
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory" on
page 177.
Message
Causes
Corrective Actions
book.book Page 52 Friday, November 20, 2009 2:56 PM