Dell PowerEdge R510 User Manual
Page 38

38
About Your System
E201A
SuperIO
failure.
Power cycle
AC.
SIO failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
E201B
Keyboard
Controller
error.
Power cycle
AC.
Keyboard
controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.If the
problem persists,
see "Getting Help" on
page 199.
E201C
SMI
initialization
failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
E201D
Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
E201E
POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 177.
If the problem persists,
see "Getting Help" on
page 199.
E2020
CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages.
See "Troubleshooting
Processors" on page 186.
Code
Text
Causes
Corrective Actions
book.book Page 38 Friday, November 20, 2009 2:56 PM