beautypg.com

Dell PowerEdge R510 User Manual

Page 30

background image

30

About Your System

E1114

Ambient Temp

exceeds

allowed range.

Ambient temperature has
a reached a point outside
of the allowed range.

See "Troubleshooting
System Cooling
Problems" on page 176.

E1116

Memory

disabled,

temp above

range.

Power

cycle AC.

Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.

Remove AC power to the
system for 10 seconds and
restart the system.

See "Troubleshooting
System Cooling
Problems" on page 176.
If the problem persists,
see "Getting Help" on
page 199.

E1210

Motherboard

battery

failure.

Check

battery.

CMOS battery is missing
or the voltage is outside of
the allowable range.

See "Troubleshooting the
System Battery" on
page 174.

E1211

RAID

Controller

battery

failure.

Check

battery.

RAID battery is either
missing, bad, or unable
to recharge due
to thermal issues.

Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 147,
and
"Troubleshooting System
Cooling Problems" on
page 176.

E1216

3.3V Regulator

failure.

Reseat PCIe

cards.

3.3 V voltage regulator
has failed.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 184.

E1229

CPU # VCORE

Regulator

failure.

Reseat CPU.

Specified processor
VCORE voltage
regulator has failed.

Reseat the processor(s).
See "Troubleshooting
Processors" on page 186.

If the problem persists,
see "Getting Help" on
page 199.

Code

Text

Causes

Corrective Actions

book.book Page 30 Friday, November 20, 2009 2:56 PM