beautypg.com

Dell PowerEdge R510 User Manual

Page 32

background image

32

About Your System

E1410

System Fatal

Error

detected.

Specified processor has an
internal error. The error
may or may not have
been caused by
the processor.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 199.

E1414

CPU # temp

exceeding

range.

Check CPU

heatsink.

Specified processor is out
of acceptable
temperature range.

Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting
Processors" on page 186
and "Troubleshooting
System Cooling
Problems" on page 176.

E1418

CPU # not

detected.

Check CPU

is seated

properly.

Specified processor is
missing or bad,
and the system is in an
unsupported
configuration.

Ensure that the specified
processor is properly
installed. See
"Troubleshooting
Processors" on page 186.

E141C

Unsupported

CPU config.

Check CPU or

BIOS revision.

Processors are in an
unsupported
configuration.

Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.

E141F

CPU # protocol

error. Power

cycle AC.

The system BIOS
has reported a processor
protocol error.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 199.

Code

Text

Causes

Corrective Actions

book.book Page 32 Friday, November 20, 2009 2:56 PM