Dell PowerEdge SC1420 User Manual
Page 14

A possible VRM 0 and VRM 1 failure
has occurred.
See "
Getting Help
."
A possible processor failure has
occurred.
Reinstall the processor, see "
Processor
" in "Installing System Components" and restart the
system.
Memory modules are detected, but a
memory failure has occurred.
Remove and reinstall all memory modules. See "
System Memory
" in "Installing System
Components." Ensure that the memory modules are proper installed. See "
Memory Module
Installation Guidelines
." Ensure that all the connector tabs are locked.
Restart the system.
A possible expansion-card failure has
occurred.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
If the problem persists, see "
Getting Help
."
A possible video card failure has
occurred.
Reinstall the video card. See "
Expansion Cards
" in "Installing System Components" and restart
the system.
If the problem still exists, install a video card that you know works and restart the system.
If the problem persists, see "
Getting Help
."
A possible diskette or hard-drive
failure has occurred.
Check all the power and data cable connections. See "
Troubleshooting a Diskette Drive
" or the
appropriate hard-drive troubleshooting procedure ("
Troubleshooting a SCSI Hard Drive
" or
"
Troubleshooting a SATA Hard Drive
") in "Troubleshooting Your System."
A possible USB failure has occurred.
Check cable connections, reinstall all USB devices, and restart the system.
No memory modules are detected.
Remove and reinstall all memory modules. See "
System Memory
" in "Installing System
Components." Ensure that the memory modules are proper installed. See "
Memory Module
Installation Guidelines
." Ensure that all the connector tabs are locked.
Restart the system.
A system board failure has occurred.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
If the problem persists, see "
Getting Help
."
Memory modules are detected, but a
memory configuration or compatibility
error exists.
Ensure that memory modules are properly installed. See "
Memory Module Installation Guidelines
"
in "Installing System Components."
Reinstall the memory modules and restart the system.
If the problem persists, see "
Getting Help
."
A possible system board resource
and/or hardware failure has occurred.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
If the problem persists, see "
Troubleshooting the System Battery
."
If the problem persists, see "
Troubleshooting System Memory
."
If the problem persists, see "
IRQ Assignment Conflicts
" in "Finding Software Solutions."
If the problem persists, see "
Getting Help
."
A possible expansion card failure has
occurred.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
If the problem persists, see "
IRQ Assignment Conflicts
" in "Finding Software Solutions."
If the problem persists, see "
Getting Help
."