beautypg.com

Dell PowerEdge C8000 User Manual

Page 67

background image

Using the Expander Flash Utility

67

For example, the command line should have the following format:
cmd>xflash -i

500650b0000472bf down fw

sas2xfwZeus_120518_1_0_2_0.fw 0

b

When the "Are you sure to download file to expander? (y/n)" message

prompt appears, press Y.

8 Download the expander firmware to flash region 2.

a

Enter the following command:
cmd>xflash -i

SASADDR down fw sas2xfwZeus_XXX.fw 2

where
SASADDR is the inband SAS address of the specified expander chip
XXX is the firmware image version number
For example, the command line should have the following format:
cmd>xflash -i

500650b0000472bf down fw

sas2xfwZeus_120518_1_0_2_0.fw 2

b

When the "Are you sure to download file to expander? (y/n)" message

prompt appears, press Y.

9 Download the manufacturing image to flash region 3.

a

Enter the following command:
cmd>xflash -i

SASADDR down mfg sas2xMfgZeus_XXX.bin 3

where
SASADDR is the inband SAS address of the specified expander chip
XXX is the manufacturing image version number
For example, the command line should have the following format:
cmd>xflash -i

500650b0000472bf down fw

sas2xfwZeus_120518_7_1_5_0.fw 3

b

When the "Are you sure to download file to expander? (y/n)" message

prompt appears, press Y.