For example, the command line should have the following format:
cmd>xflash -i
500650b0000472bf down fw
sas2xfwZeus_120518_1_0_2_0.fw 0
b
When the "Are you sure to download file to expander? (y/n)" message
prompt appears, press Y.
8 Download the expander firmware to flash region 2.
a
Enter the following command:
cmd>xflash -i
SASADDR down fw sas2xfwZeus_XXX.fw 2
where
SASADDR is the inband SAS address of the specified expander chip
XXX is the firmware image version number
For example, the command line should have the following format:
cmd>xflash -i
500650b0000472bf down fw
sas2xfwZeus_120518_1_0_2_0.fw 2
b
When the "Are you sure to download file to expander? (y/n)" message
prompt appears, press Y.
9 Download the manufacturing image to flash region 3.
a
Enter the following command:
cmd>xflash -i
SASADDR down mfg sas2xMfgZeus_XXX.bin 3
where
SASADDR is the inband SAS address of the specified expander chip
XXX is the manufacturing image version number
For example, the command line should have the following format:
cmd>xflash -i
500650b0000472bf down fw
sas2xfwZeus_120518_7_1_5_0.fw 3
b
When the "Are you sure to download file to expander? (y/n)" message
prompt appears, press Y.