Dell PowerEdge 1650 User Manual
Page 18

system board - please run SETUP program
Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.
the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See
Figure A
-2
for jumper location.
Replace the battery. See "
Replacing the System Battery
" in
"Installing System Board Options."
CPUs with different cache sizes detected
Two different types of microprocessors
are installed.
Install a correct version of the microprocessor so that both
microprocessors have the same level 2 cache size. See
"
Adding or Replacing a Microprocessor
" in "Installing
System Board Options."
Decreasing available memory
One or more memory modules improperly
seated or faulty.
Remove and reseat the memory modules. See "
Removing
Memory Modules
" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see "
Getting Help
."
Diskette drive 0 seek failure
Faulty or improperly inserted diskette,
incorrect configuration settings in System
Setup program, loose diskette interface
cable.
Replace the diskette. Run the System Setup program to
correct the diskette drive type. See "Using the System
Setup Program" in the User's Guide. Check that the
diskette drive interface cable is connected correctly. See
"
Installing Drives
."
Diskette read failure
Faulty diskette, or faulty or improperly
connected diskette drive.
Check that the diskette drive interface cable is connected
correctly. See "
Installing Drives
."
Diskette subsystem reset failed
Faulty diskette/CD drive controller
(defective system board).
Replace the system board. See "
Getting Help
."
ECC memory error
Improperly seated or faulty memory
modules.
Remove and reseat the memory modules. See "
Removing
Memory Modules
" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see "
Getting Help
."
Embedded server management error
Embedded server management is not present
Embedded server management memory
may be temporarily corrupted.
To clear the embedded server management memory, shut
down the system, disconnect the power cord(s), wait
approximately 30 seconds, and then reconnect the power
cord(s) and restart the system. If the problem persists,
see "
Getting Help
."
Error: Dell Remote Access Card initialization
failure
Defective server management card or
system board.
Replace the expansion card. See "
Installing Expansion
Cards
" in "Installing System Board Options." If the problem
persists, replace the system board. See "
Getting Help
."
Gate A20 failure
Faulty keyboard controller (defective
system board).
Replace the system board. See "
Getting Help
."
Hard disk controller failure
Hard disk read failure
Incorrect configuration settings in System
Setup program, improperly connected
hard drive, faulty hard-drive controller
subsystem (defective system board), or
loose power cable.
Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in
the User's Guide. Reinstall the hard drive. See "
Installing
Drives
." Check the interface cable and power cable
connections to the backplane board. See "
Installing
Drives
."
Invalid configuration information - please run
SETUP program
Incorrect configuration settings in System
Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See
Figure A
-2
for jumper location.
Replace the battery. See "
Replacing the System Battery
" in
"Installing System Board Options."
Invalid memory configuration detected.
Potential for data corruption exists!
Memory modules are not installed in
matched pairs.
Install memory modules in matched pairs. See "
Installing
Memory
" in "Installing System Board Options."
Invalid NVRAM configuration, resource re-
allocated
System configuration data has been
ignored.
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide.
I/O parity interrupt at address
Expansion card(s) is improperly installed
or faulty.
Reinstall the expansion card(s). See "
Installing Expansion
Cards
" in "Installing System Board Options." If the problem
persists, replace the expansion card(s).
Keyboard controller failure
Defective keyboard/mouse controller
(defective system board).
Replace the system board. See "
Getting Help
."
Keyboard data line failure
Keyboard stuck key failure
Keyboard clock line failure
Keyboard failure
Keyboard cable connector is loose or
improperly connected; defective
keyboard; defective keyboard/mouse
controller (defective system board).
Check the keyboard cable connection. Replace the
keyboard. If the problem persists, replace the system
board. See "
Getting Help
."
Memory address line failure at address, read
value expecting value
Memory high data line failure at start address
to end address
Memory high address line failure at start
address to end address
Memory double word logic failure at start
address to end address
Memory odd/even logic failure at start address
to end address
Memory write/read failure at address, read
value expecting value
Faulty or improperly seated memory
modules or defective system board.
Remove and reseat the memory modules. See "
Installing
Memory Modules
" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see "
Getting Help
."
Memory parity failure at start address to end
address
Improperly seated or faulty memory
modules.
Remove and reseat the memory modules. See "
Installing
Memory Modules
" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the