About Your System

W1228 RAID

Controller
battery
capacity <
24hr.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

Allow RAID battery to

charge to greater than 24

hours of available charge.
If problem persists,

replace the RAID battery.

See "Installing the Storage

Controller Board" on

page 282.

W1627 Power

required >
PSU wattage.
Check PSU and
config.

The system configuration

requires more power than

what the power supply can

provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

W1628 Performance

degraded.
Check PSU and
system
configur-
ation.

The system configuration

requires more power than

what the power supply can

provide, but it can boot if

throttled.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at support.dell.com/manuals.

Table 1-26. LCD Status Messages

(continued)

Code

Text

Cause