beautypg.com

Software controlled store/recall cycle, Switching waveform – Cypress STK11C68-5 User Manual

Page 10

background image

STK11C68-5 (SMD5962-92324)

Document Number: 001-51001 Rev. *A

Page 10 of 15

Software Controlled STORE/RECALL Cycle

The software controlled STORE/RECALL cycle follows.

[10, 11]

Parameter

Alt

Description

35 ns

45 ns

55 ns

Unit

Min

Max

Min

Max

Min

Max

t

RC

t

AVAV

STORE/RECALL Initiation Cycle Time

35

45

55

ns

t

SA

[10]

t

AVEL

Address Setup Time

0

0

0

ns

t

CW

[10]

t

ELEH

Clock Pulse Width

25

30

35

ns

t

HACE

[10]

t

ELAX

Address Hold Time

20

20

20

ns

t

RECALL

[10]

RECALL Duration

20

20

20

μs

Switching Waveform

Figure 11. CE Controlled Software STORE/RECALL Cycle

[10]

Notes

10. The software sequence is clocked on the falling edge of CE without involving OE (double clocking aborts the sequence).
11. The six consecutive addresses must be read in the order listed in

Table 1

on page 4. WE must be HIGH during all six consecutive cycles.

t

RC

t

RC

t

SA

t

SCE

t

HACE

t

STORE

/ t

RECALL

DATA VALID

DATA VALID

6

#

S

S

E

R

D

D

A

1

#

S

S

E

R

D

D

A

HIGH IMPEDANCE

ADDRESS

CE

OE

DQ (DATA)

[+] Feedback