EPIM SPECIFICATIONS

SEH USER’S GUIDE

A-5

A.1.4

EPIM-C

The EPIM-C supports thin-net coaxial cabling and is equipped with an
internal Cabletron Systems TMS-3 Transceiver. Use the TERM switch on
the front of the EPIM-C to set the internal 50 ohm terminator. This
eliminates the need to connect the port to a tee-connector and terminator.
Figure A-4 shows the settings for the terminator switch.

Figure A-4. EPIM-C

Connector Type

BNC receptacle, with gold center contact, for use with BNC type tee-
connectors and RG-58 thin-net cable.

Grounding

The BNC port of the Coaxial Interface Module is not internally connected
to earth ground.

EPIM-C

Internal Termination Switch
= On (internally terminated)
= Off (need external termination)

TERM

1490_34

For safety, only one end of a thin-net segment should be
connected to earth ground. Connection to earth ground at
more than one point on the segment may cause dangerous
ground currents.