CHAPTER 3: INSTALLATION

3-2

SEH USER’S GUIDE

3.2.1 Tabletop or Shelf Installation

The following subsection provides guidelines for installation on a
tabletop or shelf.

Guidelines for Tabletop and Shelf Installation

Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:

A single phase 120 Vac, 15 A, grounded power receptacle must be
located within seven feet of the location.

In a shelf installation, the shelf must be able to support 30 pounds
of static weight for each device in the stack.

The temperature for the selected location must be maintained
between 5

°

C (41

°

F) and 50

°

C (122

°

F), and fluctuate less than

10

°

C per hour.

For a free-standing shelf or tabletop installation, locate the SEH within
seven feet of its power source and with an unrestricted free surface area
21 inches wide, 18 inches deep and 6 inches high, as shown in Figure 3-1.

Figure 3-1. Shelf or Tabletop Installation