CHAPTER 4: CONNECTING TO THE NETWORK

4-2

SEH USER’S GUIDE

Connect twisted pair segments to the SEH as follows:

1. Insert the RJ45 connector from each twisted pair segment into the

desired network port on the SEH. See Figure 4-1.

Figure 4-1. SEH-24 Network Ports

2. Check that the applicable LNK LED for the port is on. If the LED is

off, perform each of the following steps until it is on:

a.

Check that the 10BASE-T device at the other end of the twisted
pair segment is powered up.

b. Verify that the RJ45 connector on the twisted pair segment has the

proper pinouts. Check the cable for continuity.

c.

Check that the twisted pair connection meets dB loss and cable
specifications outlined Chapter 2.

If a link is not established, contact Cabletron Systems Technical Support.