Cabletron Systems SEH-22 User Manual
Page 46
![background image](/manuals/61758/46/background.png)
APPENDIX A: EPIM INFORMATION
A-2
SEH USER’S GUIDE
A.1.2
EPIM-F1 and EPIM-F2
The EPIM-F1 and EPIM-F2 shown in Figure A-2 support Multimode
Fiber Optic cabling. Each EPIM has an internal Cabletron Systems
FOT-F Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA
Connectors and the EPIM-F2 is equipped with ST Connectors.
Specifications for the EPIMs are listed below.
Figure A-2. EPIM-F1 and EPIM-F2
Note
: The transmitter power levels and receive sensitivity levels listed are
Peak Power Levels after optical overshoot. Use a Peak Power Meter
compare the values given above to those measured on any particular port.
If Power Levels are being measured with an Average Power Meter, add 3
dBm to the measurement to compare the measured values to the values
listed (i.e., -33.5 dBm average + 3 dBm =-30.5 dBm peak).
Parameter
Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
Receive
Sensitivity
-30.5 dBm
-28.0 dBm
—
—
Peak Input Power
-7.6 dBm
-8.2 dBm
—
—
Transmitter Power
50/125
µ
m fiber
-13.0 dBm
-15.0 dBm
13.0 dB
17.5 dB
62.5/125
µ
m fiber
-10.0 dBm
-12.0 dBm
16.0 dB
20.5 dB
100/140
µ
m fiber
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate
Better than 10
-10
1490_30