beautypg.com

Cabletron Systems SEH-22 User Manual

Page 46

background image

APPENDIX A: EPIM INFORMATION

A-2

SEH USER’S GUIDE

A.1.2

EPIM-F1 and EPIM-F2

The EPIM-F1 and EPIM-F2 shown in Figure A-2 support Multimode
Fiber Optic cabling. Each EPIM has an internal Cabletron Systems
FOT-F Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA
Connectors and the EPIM-F2 is equipped with ST Connectors.
Specifications for the EPIMs are listed below.

Figure A-2. EPIM-F1 and EPIM-F2

Note

: The transmitter power levels and receive sensitivity levels listed are

Peak Power Levels after optical overshoot. Use a Peak Power Meter
compare the values given above to those measured on any particular port.
If Power Levels are being measured with an Average Power Meter, add 3
dBm to the measurement to compare the measured values to the values
listed (i.e., -33.5 dBm average + 3 dBm =-30.5 dBm peak).

Parameter

Typical

Value

Worst

Case

Worst

Case

Budget

Typical

Budget

Receive
Sensitivity

-30.5 dBm

-28.0 dBm

Peak Input Power

-7.6 dBm

-8.2 dBm

Transmitter Power

50/125

µ

m fiber

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125

µ

m fiber

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140

µ

m fiber

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate

Better than 10

-10

1490_30