beautypg.com

Table a-3 – Cisco 2940 User Manual

Page 56

background image

A-2

Catalyst 2940 Switch Hardware Installation Guide

OL-6157-01

Appendix A Technical Specifications

Table A-2

Fiber-Optic Port Specifications for Catalyst 2950-8TF-Switch

Fiber-Port Power Levels

100BASE-FX port

SFP module
slot

1

1.

SFP-dependent

Optical transmitter wavelength

1300 nm

2

2.

nm = nanometers

Optical receiver sensitivity for 50/125-micron cabling

–33.5 to
–11.8 dBm

3

3.

dBm = decibel milliwatt

Optical receiver sensitivity for 62.5/125-micron
cabling

–33.5 to
–11.8 dBm

Optical transmitter power for 50/125-micron cabling

–23.5 to –14 dBm

Optical transmitter power for 62.5/125-micron cabling –20 to –14 dBm

Table A-3

Catalyst 2940 Switch Agency Approvals

Safety

EMC

UL/CSA 60950

FCC Part 15 Class A

IEC 60950/EN 60950

EN 55022: 1998 (CISPR22) Class A

AS/NZS 60950

EN 55024: 1998 (CISPR24)

CE

VCCI Class A

AS/NZS 3548 Class A

CE

CNS 13438 Class A

MIC

CLEI code

USA CFR47, FCC, Part 15, Class A

ICES-003, Class A

EN55022/CISPR22, Class A, 1998

Safety

EMC

EN 55024: ITE Immunity Standard. (CE Mark), 1998

EN61000-4-2/IEC1000-4-2: Immunity to ESD

EN61000-4-3/IEC1000-4-3: Immunity to Radio
Frequency Electromagnetic Fields

EN61000-4-4/IEC1000-4-4: Immunity to Electrical
Fast Transients

EN61000-4-5/IEC1000-4-5: Immunity to Power Line
Transients (Surges)

EN61000-4-6/IEC1000-4-6: Immunity to Radio
Frequency Induced Conducted Disturbances