Catalyst 2940 Switch Hardware Installation Guide
OL-6157-01
Chapter 3 Troubleshooting
Diagnosing Common Problems
Table 3-1
Common Connectivity Problems and Their Solutions
Symptom
Possible Cause
Resolution
No connectivity to 10/100 ports
or 10/100/1000 port.
Incorrect or bad cable.
•
Remove and reconnect cable
to switch and PC. Wait 30
seconds for port status LED
on switch to turn green.
These are the results of no link at
both ends:
•
Cable not properly installed
between switch and PC.
•
A crossover cable was used
when a straight-through was
required, or vice-versa.
•
To identify a crossover
cable, see
.
•
The cable is wired
incorrectly.
•
Verify that the cable is wired
correctly. See
through
for
the correct pinouts of 10/100
cables. For the proper
application of crossover and
straight-through cables, see
the
Specifications” section on
page B-5
.
•
Replace it with a tested good
cable.
•
STP is checking for possible
network loops.
•
Wait 30 seconds for port
status LED to turn green.
No connectivity to
100BASE-FX port.
An SFP module was installed in
the switch at power on.
Note
The SFP module slots
and the 100BASE-FX
port cannot both be used
at the same time. If an
SFP module is installed
when the switch is
powered on, the
100BASE-FX port is
disabled.
Remove the SFP module, and
reboot the switch.
Note
See the
an SFP Module” section
on page 2-12
and the
Cisco Small
Form-Factor Pluggable
Modules Installation
Notes (order number
DOC-7815160=) for
procedures on removing
an SFP module.