7.3. Encoder operating parameters

Description of operating parameters

Parameter

Significance

Sense of rotation

Behaviour of the output code relating to the shaft’s sense of rotation when looking at
the flange.
CW („clockwise“) = ascending values with clockwise rotation
CCW

(„counter-clockwise“) = ascending values with counter-clockwise rotation

Resolution
(„Measuring units
per revolution“)

Number of steps per revolution, input in integral steps

Measuring range
(„Total Measuring
Range“)

Total resolution = number of steps per revolution x number of revolutions,
input in integral steps

Steps

The actual encoder position is assigned to a certain position value (referencing)



Operating parameter values

Parameter

Value range

Default setting

Data type

Sense of rotation

CW/CCW

CW

Byte

Resolution

1 to 4096

– magtivo

1 to 8192

– multivo

1 to 262144

– multivoPlus

4096
8192
262144

Unsigned 32

Measuring range

1 to 67108864 (2

26

)

– magtivo

1 to 536870912 (2

29

)

– multivo

1 to 2147483648 (2

31

)

– multivoPlus

67108864
536870912
2147483648

Unsigned 32

Peset value

0 to (measuring range - 1 step)

0