Object 0x3204 Collective information „Check Position“

0x3204_0

SDO Sub Index count

0x3204_1

scan total of SPAs ‚not in position’

0x3204_2

scan SPA with SUB bus identifier 0..31

‚not in position’

0x3204_3

scan SPA with SUB bus identifier 32..63

‚not in position’

0x3204_4

scan SPA with SUB bus identifier 64..95

‚not in position’

0x3204_5

scan SPA with SUB bus identifier 96..99

‚not in position’





0x3204_2.. 0x3204_5

The information SPA ‚not in position’ is in binary code in a 32 bit double word.


A bit entry at location 2

n

is representing a SPA with identifier n ‚not in position’




Example: read SPA with SUB- bus identifier 0..31

‚not in position’


0x 00 80 00 3C



0x00

x

x x x x

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0


Result: SPA with user identifiers 2, 3, 4, 5 and 23 are not in position







Example: scan SPA with SUB bus identifier 64..95

‚not in position’


0x00 00 00 04

0x00

x

95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64


Result: SPA with user identifier 66 is ‚not in position’