Object 0x3204 Collective information „Check Position“
0x3204_0
SDO Sub Index count
0x3204_1
scan total of SPAs ‚not in position’
0x3204_2
scan SPA with SUB bus identifier 0..31
‚not in position’
0x3204_3
scan SPA with SUB bus identifier 32..63
‚not in position’
0x3204_4
scan SPA with SUB bus identifier 64..95
‚not in position’
0x3204_5
scan SPA with SUB bus identifier 96..99
‚not in position’
0x3204_2.. 0x3204_5
The information SPA ‚not in position’ is in binary code in a 32 bit double word.
A bit entry at location 2
n
is representing a SPA with identifier n ‚not in position’
Example: read SPA with SUB- bus identifier 0..31
‚not in position’
0x 00 80 00 3C
0x00
x
x x x x
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Result: SPA with user identifiers 2, 3, 4, 5 and 23 are not in position
Example: scan SPA with SUB bus identifier 64..95
‚not in position’
0x00 00 00 04
0x00
x
95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64
Result: SPA with user identifier 66 is ‚not in position’