beautypg.com

Operators instructions cleverlevel switch, lffs, Atex, Atex gas ia – Baumer CleverLevel - LFFS User Manual

Page 8

background image

ATEX

Operators instructions
CleverLevel switch, LFFS

Ex ia IIC T5, ATEX II 1G - Installation

A Level Switch LFFS-1xx.x is Ex ia IIC T5, ATEX II 1G ap-
proved for application in hazardous areas in accordance with
the current EU directives. The product must be installed in
accordance with prevailing guidelines for zone 0 with a barrier

Ex-data

Supply range

24...30 VDC

Temperature class T1...T5 Pls. see above table
Internal inductivity L

i

<10 µH

Internal capacity C

i

<33 nF


Barrier data

U

<30 VDC

I

<0.1 A

P

<0.75 W

Connection type Ambient temperature Media temperature

(max. allowed)

Note

G½ hygienic

-40 … +85 °C

+85 °C

3A DN38

-40 … +60 °C

+95 °C

1)

-40 … +40 °C

+115 °C

1)

100 mm

-40 … +85 °C

+85 °C

Sliding connection

-40 … +60 °C

+155 °C

1)

-40 … +40 °C

+175 °C

1)

250 mm

-40 … +85 °C

+85 °C

Sliding connection

-40 … +60 °C

+195 °C

1)

-40 … +40 °C

+200 °C

1)

Conditions for Ex certification

1) Provided that
the sensor tip
at the instru-
ment is the
only part in
contact with
the media

ATEX Gas ia

LFFS-1xx.x
with PNP output

Safe area

+ 22...120 VDC
or
- 90...253 VAC

Note:

For PNP output the barrier module
PFOFSI3-B25100-ALG-LS
is required for functional purposes.

PF

O

F

S

I3

-B2

51

00

-AL

G

-L

S

NPN out

LFFS-1xx.x
with NPN output

Note:

For NPN output only!
A standard barrier may be used

St

an

da

rd

b

arri

er

Two-channel
ZENER barrier

www.baumer.com

Operators instructions: 11109132 02 EN Page 8 / 12

Note:

There is an electrical connection between intrinsic safe circuit
and housing due to the measurement principle