beautypg.com

Parameter commands – Baumer N 152 User Manual

Page 15

background image

N 152

www.baumer.com

15

4.2.9. Indicate optional column of figures in upper line „t“ (74h)

This command is utilized to indicate a 5-digit number in the upper line of the display. The numerical column is
indicated less dot respectively comma. Preceding zeroes as well as both arrows are suppressed. The bottom
line still indicates the actual value.
The numerals are indicated in the display until any command except „t“, „u“ or „R“ is received. The number will
be retained after power failure.

Example: (Column of figures = 054321)

SOH

Adr

Cmd

Column of figures = 054321

EOT

CRC

Transmission

01h

20h

74h

30h

35h

34h

33h

32h

31h

04h

C6h

SOH

Adr

Cmd

Column of figures = 054321

EOT

CRC

Response

01h

20h

74h

30h

35h

34h

33h

32h

31h

04h

C6h

4.2.10. Indicate optional column of figures in bottom line „u“ (75h)

The command is utilized to indicate a 5-digit column of figures in the bottom line of the display. The number is
indicated less dot respectively comma. Preceding zeroes as well as both arrows are suppressed. The upper line
still indicates actual target or the column of figures.
The column is indicated until any optional command except „t“, „u“ or „R“ is received by the interface. The
number will be retained after power failure.


Example: (Column of figures = 012345)

SOH

Adr

Cmd

Column of figures = 012345

EOT

CRC

Transmission

01h

20h

75h

30h

31h

32h

33h

34h

35h

04h

B6h

SOH

Adr

Cmd

Column of figures = 012345

EOT

CRC

Response

01h

20h

75h

30h

31h

32h

33h

34h

35h

04h

B6h


Note:
Command “t” in conjunction with command “u” enables indication of a 10-digit number.
Both columns are not saved in EEPROM.

4.3. Parameter commands

Command

code

Data amount

in bytes

read

write

Broad-

cast

Saved in

EEPROM

Significance

a (61h)

5

X

X

-

X

Read / write general parameters

b (62h)

8

X

X

-

X

Parameter: tolerance compensation, window

c (63h)

8

X

X

-

X

Parameter: Scaling of spindle pitch

g (67h)

12

X

X

-

X

Parameter: Limit positions MIN, MAX

h (68h)

12

X

X

-

X

Parameter: Switching points motor speed

i (69h)

1

X

X

X

X

Parameter: mm / inch

j (69h)

3

X

X

X

X

Parameter: Timeout bus error

k (6Bh)

9

X

X

-

X

Parameter: motor system times

l (6Ch)

5

X

X

-

X

Parameter: Jog function

m (6Dh)

5

X

X

-

X

Read / write general parameters