9. Programming plan

Line 11-17 Status lines 1-7
0

Parameter enabled for programming

1

Delete resp. Input lock

2

Skip parameter

Line 21

Operating mode

0

Adding (reset to SC)

1

Subtracting (reset to P2)

2

Subtracting; but output contact at SC, auto-
matic reset at 0

Line 22

Preset mode

0

Step preset

1

P1-trailing preset

Line 23

Reset

0

With automatic reset

1

w/o automatic reset

Line 24

Decimal point in PC, P1, P2, tot, SC

0

None

1

0000.0

2

000.00

3

00.000

Line 30

Count mode

0

Track A UP/DOWN signal at B where required

1

Subtracting (A-B)

2

Adding (A+B)

3

Track A 90° B Single evaluation

4

Track A 90° B Double evaluation

5

Track A 90° B Quadruple evaluation

6

Hour counter with preset

7

Same as 6 but with start and stop

Line 31

Frequency track A

0

10 kHz

1

25 Hz

2

3 Hz

Line 32

Frequency track B

0

10 kHz

1

25 Hz

2

3 Hz

Line 33

Input logic

0

PNP Trigger threshold 6 V

1

NPN Trigger threshold 6 V

2

PNP Trigger threshold 3 V

3

NPN Trigger threshold 3 V

Line 34

Functionality control input 1 (terminal 9)

0

Reset static

1

Reset edge-triggered

2

Reset totalizer edge-triggered

3

Stop

4

Hold

5

Programming lock

6

Key lock

7

Print

8

Outputs IN (P1,P2)

9

Outputs IN (P1,P2) and reset fl.

Line 35

Reaction time of control input 1

0

30 ms

1

100 µs







Line 36

Functionality control input 2 (terminal 10)

0

Reset static

1

Reset edge-triggered

2

Reset totalizer edge-active

3

Stop

4

Hold

5

Programming lock

6

Key lock

7

Print

8

Outputs OUT (P1,P2)

Line 38

Adoption of presets P1,P2,SC

0

Immediately effective

1

Upon reset

Line 40

Output logic of digital outputs

0

Both outputs normally closed

1

P1 normally open, P2 normally closed

2

P1 normally closed, P2 normally open

3

Both outputs normally open

Line 41

Output time P1

0.25

Default

0.01

Min.

99.99

Max.

Line 42

Output time P2

0.25

Default

0.01

Min.

99.99

Max.

Line 43

Time range hour counter

0

999s 99/100s

1

99min 59s 9/10s

2

999min 59s

3

999h 59min

Line 44

Rapid preset recognition

0

Standard

1

Rapid

Line 50

Code

0000

Code not active

:

9999

Line 51

Baud rate

0

4800 Baud

1

2400 Baud

2

1200 Baud

3

600 Baud

Line 52

Parity

0

Even Parity

1

Odd Parity

2

No Parity

Line 53

Stop bits

0

1 Stop bit

1

2 Stop bits

Line 54

Identifier

00

Default

00

Min.

99

Max.