beautypg.com

7installation – Baumer BA Scatec2 User Manual

Page 6

background image

Manual SCATEC-2

11

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland

7

Installation

7.1

Electrical connection

Make the electrical connections as specified in Sections 10.2 Electrical data and 10.3 Pin assignement.

7.2

Mounting

(1) Mount the sensor at the nominal working

distance h (+/-3 mm) with the front
window parallel to the conveying plane.

(2) Adjust the sensor so that the laser beam

is aimed towards the edges to be
counted. When mounted correctly, the
overlap of the copies is facing in the
same direction as indicated in the
alignment aid. Note: the laser beam is
focused into a line which must be aligned
in parallel to the edge to be detected!

(3) Block the laser beam after the objects

whenever possible.

(4) Keep the window clean (remove any

fingerprints after mounting!).

(5) A direct line of sight from the laser impact

point to the entire front window must be
ensured.

Line focus perpendicular to
the Scatec housing

Beam blocker

+/- 3°

1

3

2

1

2

Clean window

4

5

Manual SCATEC-2

12

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland

Nominal working distance h FLDK 110x1003/Sxx

40 mm above the conveyor belt

FLDK 110x1005/Sxx

100 mm above the conveyor belt

FLDK 110x1006/Sxx
The resolution is dependent on the distance. The highest resolution is
achieved at the nominal working distance. (See also Section 10.6
Specific application data
)

Angular tolerance

max. +/- 3°

Overlap orientation

The copies are counted when the edge facing the laser beam moves
through the beam. If an edge faces away from the beam, it is not
detected. Tail edges are therefore not counted unless they face upwards.

Running direction

The SCATEC-2 permits both running directions. The edges facing the
laser beam (front edges) are detected by the sensor regardless of the
running direction.

Front window

The direct line of sight from the impact
point of the laser to the entire front window
must not be obstructed by any hardware in
a distance range

d = 0 – 80 mm FLDK 110x1003/Sxx

d = 0 – 120 mm FLDK 110x1005/Sxx

FLDK 110x1006/Sxx

If mountings or other components are close
to this zone for any reason, you should
consult a technician from Baumer Electric
AG.