beautypg.com

Baumer BA Scatec2 User Manual

Page 17

background image

Manual SCATEC-2

33

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland





Fault

Possible causes

Corrective actions (see manual section x.x)

a) Apart from the edges, there are
other patches on the copies which
cause false pulses.

Prevent critical patches on the copies.

b) Laser beam on beam blocker
causes false pulses.

Adjust beam blocker correctly (yellow edge LED
must never light when the laser beam strikes the
beam blocker).

c) Unblocked laser beam is reflected
and causes false pulses.

Install beam blocker at proper distance.

2

Scatec counts more
copies than actually
pass the sensor

d) Conveyor belt stands still and
vibrates while an edge is still in the
laser beam.

This problem can be eliminated only by
synchronizing the sensor to the conveyor speed.
Scatec-10 and –15 can be synchronized.









Manual SCATEC-2

34

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland

14 Varying data for customized FLDK 110x10/xxxxxx