beautypg.com

4 output connection – Baumer BA Scatec2 User Manual

Page 13

background image

Manual SCATEC-2

25

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland

10.4

Output connection

10.4.1

Push-pull output (FLDK 110G...)

Manual SCATEC-2

26

Baumer Electric AG

Version 2011-05

www.baumer.com

Frauenfeld, Switzerland

10.4.2

Opto-isolated output (FLDK 110C...)

Pin 2

Load

Pin 1

Load

Output connected as

Current source

Current sink

V

2

GND

GND

V

1

typ. 0V

min. Vout - 4V

typ. Vout

max. 4V

Vout

polyfuse

Pin 6

Pin 2

Pin 1

Pin 3

V

+V

out

Pin 1

+V

out

V

Pin 2

+V

out

-V

out

Sensor

+V

S

GND

+V

S

Operating voltage (+10VDC ... +30VDC)

+V

out

Signal output +

-V

out

Signal output -

GND

0 V

R

Load

maximum 50 kOhm

I

Load

maximum 100 mA

switchable voltage (+Vout minus -Vout) maximum 40 V