Dell POWEREDGE 2950 User Manual
Page 24

24
About Your System
E1811
HDD ## Rbld Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a Hard
Drive" on page 124. If the
problem persists, see your RAID
documentation.
E1812
HDD ## Removed
The specified hard drive has been
removed from the system.
Information only.
E1913
CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E1A11
PCI Rsr Config
PCI risers are not configured
correctly; some invalid
configurations may prevent the
system from powering on.
See "Expansion-Card Riser
Boards" on page 98.
E1A12
PCI Rsr Missing
One or all of the PCI risers is
missing, preventing the system
from powering on.
Information only.
E1A14
SAS Cable A
SAS cable A is missing or bad.
Reseat the cable. If problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 69.
E1A15
SAS Cable B
SAS cable B is missing or bad.
Reseat the cable. If problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 69.
E2010
No Memory
No memory is installed in the
system.
Install memory. See "Installing
Memory Modules" on page 90.
E2011
Mem Config Err
Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 120.
E2012
Unusable Memory
Memory is configured, but not
usable. Memory subsystem
failure.
See "Troubleshooting System
Memory" on page 120.
E2013
Shadow BIOS Fail
The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page 120.
E2014
CMOS Fail
CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 147.
E2015
DMA Controller
DMA controller failure.
See "Getting Help" on page 147.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
Book.book Page 24 Friday, February 3, 2006 11:09 AM