22
About Your System
E1422
CPU Machine Chk
The system BIOS has reported a
machine check error.
See "Getting Help" on page 147.
E1610
PS # Missing
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 118.
E1614
PS # Status
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 118.
E1618
PS # Predictive
Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
See "Troubleshooting Power
Supplies" on page 118.
E161C
PS # Input Lost
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for
the specified power supply. If
problem persists, see
"Troubleshooting Power Supplies"
on page 118.
E1620
PS # Input Range
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for
the specified power supply. If
problem persists, see
"Troubleshooting Power Supplies"
on page 118.
E1624
PS Redundancy
The power supply subsystem is no
longer redundant. If the last
supply fails, the system will go
down.
See "Troubleshooting Power
Supplies" on page 118.
E1710
I/O Channel Chk
The system BIOS has reported an
I/O channel check.
See "Getting Help" on page 147.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
Book.book Page 22 Friday, February 3, 2006 11:09 AM