Dell POWEREDGE 2950 User Manual
Page 25

About Your System
25
E2016
Int Controller
Interrupt controller failure.
See "Getting Help" on page 147.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on page 147.
E2018
Prog Timer
Programmable interval timer
error.
See "Getting Help" on page 147.
E2019
Parity Error
Parity error.
See "Getting Help" on page 147.
E201A
SIO Err
SIO failure.
See "Getting Help" on page 147.
E201B
Kybd Controller
Keyboard controller failure.
See "Getting Help" on page 147.
E201C
SMI Init
System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 147.
E201D
Shutdown Test
BIOS shutdown test failure.
See "Getting Help" on page 147.
E201E
POST Mem Test
BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 120. If problem
persists, see "Getting Help" on
page 147.
E201F
DRAC Config
Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific error
messages.
E2021
Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 120.
E2022
POST Fail
General failure after video.
Check screen for specific error
messages.
E2110
MBE Crd # DIMM ##
& ##
One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE). If no memory card is
present, the "Crd #" string is left
out of the message.
See "Troubleshooting System
Memory" on page 120.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
Book.book Page 25 Friday, February 3, 2006 11:09 AM