Dry fertilizer outlet housing, Fertilizer chains, Squeeze pump roller bushings – Great Plains PT8030 V1013 Operator Manual User Manual
Page 47: Squeeze pump main metering shaft, Seasonally, Twice daily

45
Section 5 Maintenance and Lubrication
PT6030 and PT8030 Pull-Type Planter 401-032M-A
10/10/12
Great Plains Mfg., Inc.
Dry Fertilizer Outlet Housing
Located on each outlet housing (1 each)
Type of Lubrication: Grease
Quantity: Until grease begins to emerge.
10
As
Required
Fertilizer Chains
Lubricate all chains at intervals to maintain freedom at every
chain link joint. Spray chains if planter is going to be idle to
prevent the chains from rusting and becoming stiff. Stiff
chains will cause metering inaccuracies.
Type of Lubrication: Spray Lube
15701
Squeeze Pump Roller Bushings
Located on the ends of the squeeze pump
roller shafts (6 total)
Type of Lubrication: Grease
Quantity: Until grease begins to emerge.
12567
Seasonally
Squeeze Pump Main Metering Shaft
Located near ends of squeeze pump main
metering shaft (2 total)
Type of Lubrication: Grease
Quantity: Until grease begins to emerge.
Twice Daily
16864
12566