Section 3 Adjustments

10/10/12

PT6030 and PT8030 Pull-Type Planter 401-032M-A

Great Plains Mfg., Inc.

Recalibrating Granular Chemical Meters
If it should ever become necessary to recalibrate the gran-
ular meter on the chemical hopper, proceed as follows.

1.

Remove and empty hopper. Turn hopper upside
down.

2.

Turn hopper knob shown in Figure 3-3 to 10.

3.

See Figure 3-4. Loosen screws (1) in metering gate.

4.

Insert calibration tool (2).

5.

Re-adjust dial to 04.

6.

Slide gate (3) to tool.

7.

Retighten screws. Re-install hoppers, refill and check
per previous instructions.