beautypg.com

Data retention and endurance, Capacitance, Thermal resistance – Cypress CY14B104LA User Manual

Page 9: Ac test conditions

background image

PRELIMINARY

CY14B104LA, CY14B104NA

Document #: 001-49918 Rev. *A

Page 9 of 23

AC Test Conditions

Input Pulse Levels ....................................................0V to 3V

Input Rise and Fall Times (10% - 90%) ........................ <3 ns

Input and Output Timing Reference Levels .................... 1.5V

Data Retention and Endurance

Parameter

Description

Min

Unit

DATA

R

Data Retention

20

Years

NV

C

Nonvolatile STORE Operation

200

K

Capacitance

In the following table, the capacitance parameters are listed.

[12]

Parameter

Description

Test Conditions

Max

Unit

C

IN

Input Capacitance

T

A

= 25

°C, f = 1 MHz,

V

CC

= 0 to 3.0V

7

pF

C

OUT

Output Capacitance

7

pF

Thermal Resistance

In the following table, the thermal resistance parameters are listed.

[12]

Parameter

Description

Test Conditions

48-FBGA

44-TSOP II 54-TSOP II

Unit

Θ

JA

Thermal Resistance
(Junction to Ambient)

Test conditions follow standard test methods
and procedures for measuring thermal
impedance, in accordance with EIA/JESD51.

28.82

31.11

30.73

°C/W

Θ

JC

Thermal Resistance
(Junction to Case)

7.84

5.56

6.08

°C/W

Figure 5. AC Test Loads

3.0V

OUTPUT

5 pF

R1

R2

789

Ω

3.0V

OUTPUT

30 pF

R1

R2

789

Ω

for tri-state specs

577

Ω

577

Ω

Note

12. These parameters are guaranteed but not tested.

[+] Feedback