566-046E
Bypass Valve
106.Attach hoses
to bypass valve
(Models 5317-5323
only). Hoses and fittings will have color ties to get hoses
hooked up properly.
Note: See TC5317-TC5323 Hydraulic Down Pressure in “Op-
erator’s Manual” for adjusting bypass valve.
Pilot Check Valve
107.Attach hoses
to bypass valve
(Models 5317-5323
only) located on right truss. Hoses and fittings will have
color ties to get hoses hooked up properly.
Install Depth Control Valve and O-Ring Fittings
Refer to Figure 23
108.Thread elbow (adjustable stud) fitting
into left port of
depth stop valve
. Thread straight (non- adjustable
stud) fittings
into front port of depth control valve
.
109.Tighten as shown in steps 103, 104.
Figure 21
Bypass Valve
42638
U
D
F
B
L
R
1
2
1
1
2
Figure 22
Pilot Check Valve
41623
1
2
1
1
2
Figure 23
Depth Control Valve Fittings
41671
U
D
F
B
L
R
2
1
3
3
1
2