6.2. GENERAL STORAGE PROCEDURES
T
O
PROTECT
AUGER
IN
STORAGE
DURING
THE
OFF
SEASON
:
1. Lower the auger to full down position with a slight tension on cable.
2. Lubricate all grease fittings per maintenance procedures.
3. Check oil level in gear box and refill if needed, half full only. Do not overfill.
4. Inspect auger for damage and note any repairs required. Order replacement
parts from your dealer.
5. Check tire pressure and inflate to 24 psi (165 kPa).
6. Cover motor with protective cover from weather.
7. Tow auger to storage site and chock wheels.
Winch
Note: Service
winch with auger in
fully lowered posi-
tion and cable
slack.
Keep a film of grease on gears.
Regularly
Oil the ratchet pawl pivot, bushings, and pinion threads.
Do not get oil or grease on brake discs.
Occasionally
Replace brake discs if less than 1/16” thick.
As required
Check for proper ratchet pawl operation.
When cranking in (clockwise) = loud clicking
When cranking out (counterclockwise) = no clicking and
ratchet pawl fully engaged into gear teeth
Regularly
Area
Maintenance
Frequency
CAUTION
Support discharge end of auger before
removing or replacing any parts on the
undercarriage.