beautypg.com

General storage procedures, Caution – Wheatheart GHR 80/100 x 31-71ft Augers EMD User Manual

Page 46

background image

6. M

AINTENANCE

& S

TORAGE

W

HEATHEART

- G

RAIN

A

UGER

EMD

6.2. G

ENERAL

S

TORAGE

P

ROCEDURES

GHR 80

X

31’-71’ & 100

X

31’-71’

46

30642 R0

6.2. GENERAL STORAGE PROCEDURES

T

O

PROTECT

AUGER

IN

STORAGE

DURING

THE

OFF

SEASON

:

1. Lower the auger to full down position with a slight tension on cable.
2. Lubricate all grease fittings per maintenance procedures.
3. Check oil level in gear box and refill if needed, half full only. Do not overfill.
4. Inspect auger for damage and note any repairs required. Order replacement

parts from your dealer.

5. Check tire pressure and inflate to 24 psi (165 kPa).
6. Cover motor with protective cover from weather.
7. Tow auger to storage site and chock wheels.

Winch

Note: Service
winch with auger in
fully lowered posi-
tion and cable
slack.

Keep a film of grease on gears.

Regularly

Oil the ratchet pawl pivot, bushings, and pinion threads.

Do not get oil or grease on brake discs.

Occasionally

Replace brake discs if less than 1/16” thick.

As required

Check for proper ratchet pawl operation.

When cranking in (clockwise) = loud clicking
When cranking out (counterclockwise) = no clicking and
ratchet pawl fully engaged into gear teeth

Regularly

Area

Maintenance

Frequency

CAUTION

Support discharge end of auger before
removing or replacing any parts on the
undercarriage.