beautypg.com

Appendix a – ClearOne XAP TH1 User Manual

Page 19

background image

TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760

A

The XAP TH1 accepts serial commands via the RS-232 serial port. The
RS-232 serial port default protocol is 9,600, 8 bits, 1 stop bit, no parity.
The commands in this section pertain only to the XAP TH1.

Command Structure

The structure of serial commands is as follows:

The command, then any additional options in the order that they appear
in the command descriptions on the following pages.

Example: A command to enable auto-answer on the XAP TH1 would
have the command line: AA 1. In this command line, AA=command,
1=on state). If a command calls for a “null” value, leave a blank in the
command line (e.g. “AA” would return the current state of auto-answer
on the TH1).

Commands can use uppercase or lowercase letters. Return values
always use uppercase letters. In order for a command to be recognized
by the serial port, the command must be terminated by a carriage
return.

Appendix A

Serial Commands

APPENDIX A

• SERIAL COMMANDS

15