Sargent, Lfic (removable core) cylinders – SARGENT 6300 Series Removable Core User Manual
Page 2

2) Calculate Bottom Pins and Master Splits
Find correct size for Bottom and Master Splits from operating key's list
(a)* * * * * * BOTTOM PINS * * * * * * * *
2
1
2
1
2
2
(Smallest number in each chamber)
(b)* * * * * * MASTER SPLITS * * * * * * *
2
8
2
2
4
8
(Difference in smallest and largest number in each chamber)
3) Calculate Value of Control Splits
3.3 CONTROL KEY BITTING
4
9
6
5
6
0
(3.1) A number 8 appears on this line in positions 3 and 4
-
-
8
8
-
-
(3.2) Insert bitting of positions 3 and 4 of control key.
and add to number 8’s in positions 3 and 4
+6
+5
3.3 CONTROL PIN FACTOR
=
14
13
(3.4) Subtract largest number in positions 3 and 4
from list of operating keys from control pin factor
-4
-3
(c)* * * * * * CONTROL SPLITS * * * * * * * *
=
10
10
4) Calculate Top or Driver Pin
(Total Stack Value)
15
15
20
20
15
15
(4.1) Add value of: (a) Bottom Pins, + (b) Master Splits
+ (c) Control Splits).Enter total here.
4
9
14
13
6
10
(4.2) Subtract total from TOTAL STACK VALUE above.
(d) (4.3) Enter values on this line. DRIVER SPLITS (Master Splits)
11
6
6
7
9
5
5) Pinning Assembly Matrix
Example of pinning matrix for above key bittings.
Transfer Values labeled
(d) Driver Splits
11
6
6
7
9
5
(a), (b), (c), (d) from items
(c) Control Splits
-
-
10
10
-
-
2, 3, and 4 above.
(b) Master Splits
2
8
2
2
4
8
(a) Bottom Pins
2
1
2
1
2
2
Stack Total
15
15
20
20
15
15
Limits
SARGENT
®
LFIC (Removable Core) Cylinders
Template 6300 & 11-6300 & 10-6300 LFIC (Removable Core) Cylinder
The following is an example showing how to select the pin segments for each chamber of
the SARGENT 6300 series LFIC (removable core). Use this as a template for calculating
the correct pin loads.
I____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
|____|____|____|____|____|____|
1) List of Operating Keys
Sample
Sample
KEY SYMBOLS
BITTINGS
List Day Changes/MK’s GM’s etc
.
GM “A”
4 9
4
1
6
0
|____|____|____|____|____|____| |____|____|____|____|____|____|
Do Not list bitting of
MK “AA”
4 9
2
3
6
0
|____|____|____|____|____|____| |____|____|____|____|____|____|
the Control key in this area.
CK “AA1”
2 1
2
3
2
2
|____|____|____|____|____|____| |____|____|____|____|____|____|
-
8
15
15
20
20
15
15
8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Sample
Copyright © 2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing
Company is prohibited.
A6409K 12/01/11