Assembly instructions for el980 mullion – SARGENT Electrical Lockable Mullions User Manual
Page 2
ASSEMBLY INSTRUCTIONS FOR EL980 MULLION
Top
retainer
Strain relief
Mullion
Retaining arm
Latchbolt
Set screw
for stabilizing
mullion location
inside retainer
Retaining pin
ASSEMBLY INSTRUCTIONS FOR L980S & 12-L980 STEEL MULLIONS
Keyway
Cylinder
Blocking Ring
5/64
”
Allen
Wrench
“
1
2
3
Copyright © 2005, 2008-2012 Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part without the
express written permission of Sargent Manufacturing Company is prohibited.
A7195D 3/12
Installation of cylinder:
1. Depress latchbolt and hold fully retracted.
2. Carefully thread cylinder with blocking ring into
lock assembly until it bottoms out.
3. Unscrew the cylinder orienting keyway at bottom.
4. Release latch bolt. Note: If latch bolt is not
fully projected loosen cylinder an additional
1-2 full turns.
5. Tighten set screw with 5/64" Allen Wrench
through access hole in side of mullion.
6. Check operation of cylinder and lock assembly.
Note: Key only turns counter-clockwise.
Install standard
strain relief (not supplied). Insert
wire so
wire connector is 2" from base of top
retainer and tighten securely.
With cylinder installed, place mullion into bottom
retainer and swing mullion up until the
retaining arm
can be placed over the
retaining pin. With mullion
supported, connect wire connectors. Tuck wires into
slot while pushing mullion into the latched position.