beautypg.com

SARGENT AD8500 Narrow Design Rim Exit Device User Manual

604 rub strip installation instructions

background image

604 Rub Strip Installation Instructions

Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in

whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

A8148:A 11-16-12

Step 1: (Note: 657 Strike must be installed before

proceeding with 604 Rub Strip installation.)

Measure the distance between the front face of

the strike and the front face of the door frame.

Step 2: Using this measurement, cut the 604 Rub Strip

to the length needed.

Step 3: Drill and tap four #6-32 holes into the door

frame in the locations shown.

Step 4: Secure the 604 Rub Strip to the door frame

using the four #6-32 x ¼” screws provided.

FOR INSTALLATION ASSISTANCE CALL SARGENT AT 1-800-727-5477 / www.sargentlock.com

X

X +0.00 / -0.25

4X #6-32 UNC THRU

2X 1.25

2X .50

2X 1.00

CL OF STRIKE

& RUB STRIP