SARGENT 2408 Fire Guard Electromechanical Closer-Holder User Manual
Sargent, 2468 fireguard, Caution
SARGENT
®
12-2468 FIREGUARD
®
Closer-Holder Device
PULL SIDE INSTALLATION INSTRUCTIONS
CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE.
For assistance, contact SARGENT at 800-810-WIRE (9473) or www.sargentlock.com
1
Right Hand
A7694C
1
NOTE: AN AUXILIARY DOOR STOP IS REQUIRED AT HOLD OPEN
CAUTION:
1. DISCONNECT ALL POWER BEFORE INSTALLATION
2. ALL WIRING TO BE PERFORMED BY QUALIFIED
PERSONNEL TO COMPLY WITH ALL APPLICABLE
LOCAL CODES.
3. MAXIMUM WIRE SIZE IS 18 AWG.
!
351 Closers are
non-handed. RH
must be on top for
right hand doors.
LH must be on
top for LH doors.
Use enclosed template and drill and tap door and frame for 12-24 machine screws, and prepare hole for conduit.
Do not drill through
channel, as damage will occur voiding warranty.
Install closer body to door with spring power nut away from hinge.
Left hand shown.
Spring
Power
Nut
Left Hand
3
To provide clearance for cover, install rubber spacer to
mounting plate (frame side) in between conduit openings.
Place round
bumper here
frame side of
mounting plate
4
Secure track to frame with electronics away from hinge with screws
provided. Secure conduit or cable (not supplied) per local codes.
Wire unit according to wiring shown on page 3.
Remove knockout piece from cover on side
facing frame. Install cover as shown.
4A
For retrofit 2467 installation: Install track using screws
shown. Then mark remaining hole, remove track and drill
and tap.
5
Index
Mark on
Spindle
45°
Positioning of Arm When
Assembling to Spindle
Hinge
R. H. Door
Closer spindle,
Washer and Screw
Use screw and washer to secure main arm to spindle with index mark as shown.
R. H.
WARNING:
IF NOT PROPERLY INDEXED,
DOOR CLOSER WILL NOT
FUNCTION PROPERLY.
!
!
Hinge
Index
Mark on
Spindle
45°
L. H. Door
L. H.
Positioning of Arm When
Assembling to Spindle
Closer spindle,
Washer and Screw
2
IMPORTANT NOTE: Fire Alarm Control Panels that cannot ignore a 0.5 second closure during a power cycle, can not be used with a
12- Fireguard (smoke detector) product. For more information see bottom of this page or contact SARGENT Technical Support.
NOTE: The Smoke Detector on the 12- Fireguard product has a momentary contact closure of the Alarm output pins 1 and 2 when incoming power is applied or removed from the Fireguard unit.
Conventional FACP’s (Fire Alarm Control Panels) may not have circuitry to compensate for this momentary short of 0.5 seconds or less across pins 1 and 2 and may detect a fault, while Addressable
FACP’s have the necessary circuitry to compensate for this. For FACP’s that cannot ignore a 0.5 second closure during a power cycles do not use the 12- Fireguard (smoke detector) products.
Contact SARGENT Technical Support for more details.
Copyright © 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All
rights reserved. Reproduction in whole or in part without the express written permission of
Sargent Manufacturing Company is prohibited.
4
3
4
-1
/8
"
2
5
-5
/8
"
2
9
"
2
1
-3
/8
"
1
3
-3
/4
"
(4
)
#
1
2
-2
4
x
2
-1
/2
"
F
la
t
h
e
a
d
m
a
ch
in
e
sc
re
w
s
T
ra
ck
A
ss
e
m
b
ly
3
5
1
D
o
o
r
C
lo
se
r
4
-3
/4
"
1
-1
/2
"
9
/1
6
"
B
o
tt
o
m
o
f
Ja
m
b
2
"
9
"
2
"
4
-1
1
/1
6
"
C
H
in
g
e
:
B
u
tt
s,
sw
in
g
cl
e
a
r
a
n
d
o
ff
se
t
p
iv
o
ts
L
(4
)
#
1
2
x
3
"
W
o
o
d
sc
re
w
s
o
r
#
1
2
-2
4
x
2
-1
/4
"
F
la
t
h
e
a
d
m
a
ch
in
e
sc
re
w
s
2
-1
/2
"
1
/2
"
S
e
e
D
e
ta
il
“
A
”
T
o
p
o
f
d
o
o
r
R
e
ce
ss
M
o
rt
is
e
N
u
t
H
e
a
d
s
W
h
e
n
C
o
n
fl
ic
t
w
it
h
S
to
p
O
cc
u
rs
1
/8
"
5
/8
"
R
e
ce
ss
m
o
rt
is
e
n
u
t
h
e
a
d
a
s
sh
o
w
n
S
to
p
D
o
o
r
Do
or
1
/8
"
M
a
x
.
F
ra
m
e
p
ro
je
ct
io
n
2
"
M
in
.
F
ra
m
e
fa
ce
1
-7
/8
"
1
-9
/1
6
"
3
-7
/8
"
2
-3
/1
6
"
Gla
ss
4
"
3
T
o
p
o
f
d
o
o
r
F
ra
m
e
1
-3
/1
6
"
3
/4
"
D
e
ta
il
“
A
”
1
-1
/8
"
(2
)
1
5
/1
6
"
C
o
n
d
u
it
h
o
le
s
fo
r
co
n
ce
a
le
d
w
ir
in
g
B
o
tt
o
m
o
f
ja
m
b
R
E
L
E
A
S
E
D
A
T
E
O
C
T
0
3
T
E
M
P
L
A
T
E
N
O
.
A
7
7
0
0
A
D
A
T
A
S
H
E
E
T
1
2
-2
4
6
8
C
lo
se
r-
H
o
ld
e
r
w
it
h
S
m
o
k
e
D
e
te
ct
o
r
U
n
it
,
P
u
ll
S
id
e
M
o
u
n
ti
n
g
N
O
T
E
S
1
.
R
e
in
fo
rc
e
m
e
ta
l
d
o
o
rs
a
n
d
fr
a
m
e
s
p
e
r
A
N
S
I
A
2
5
0
.8
&
S
D
I-
1
0
0
,
1
2
g
a
u
g
e
re
co
m
m
e
n
d
e
d
.
2
.
R
ig
h
t
h
a
n
d
d
o
o
r
sh
o
w
n
,
le
ft
h
a
n
d
o
p
p
o
si
te
.
3
.
F
o
r
n
a
rr
o
w
ra
il
d
o
o
rs
(m
in
im
u
m
2
-1
/8
"
),
u
se
3
5
1
-A
d
ro
p
p
la
te
;
se
e
te
m
p
la
te
A
6
7
7
2
.
A
7
6
9
4
C
C
o
p
yr
ig
h
t
©
2
0
0
8
,S
a
rg
e
n
t
M
a
n
u
fa
c
tu
ri
n
g
C
o
m
p
a
n
y,
a
n
A
S
S
A
A
B
LO
Y
G
ro
u
p
c
o
m
p
a
n
y.
A
ll
ri
g
h
ts
re
se
rv
e
d
.R
e
p
ro
d
u
c
ti
o
n
in
w
h
o
le
o
r
in
p
a
rt
w
it
h
o
u
t
th
e
e
xp
re
ss
w
ri
tt
e
n
p
e
rm
is
si
o
n
o
f
S
a
rg
e
n
t
M
a
n
u
fa
c
tu
ri
n
g
C
o
m
p
a
n
y
is
p
ro
h
ib
it
e
d
.