Step 7. Connect wiring harness of 433MHz Receiver to unit as
shown
Step 8. Toggle circuit breaker switch to RESET position to turn
power input to unit on.
Confirm LED on 433MHz Receiver is flashing red.
The 433MHz Receiver can learn up to 12 transmitters.
Programming of a 13th transmitter will dump the code
programmed for the first transmitter in the sequence.
Follow the directions below to store a transmitter’s code into
the 433MHz Receiver located on the door operator.
1. Door operator should have input power turned on.
Confirm LED on 433MHz Receiver is flashing red.
2. Press 433MHz Receiver’s programming button for less
than 2 seconds and release. The 433MHz Receiver’s LED
changes from blinking red to solid green.
3. Press and release the button on a 433MHz FOB (or RF
Wall Switch on any 433MHZ transmitter being
programmed to activate the MP3000) once.Verify 433MHz
Receiver’s LED changes to solid red. The 433MHz
Receiver is now learning the transmitter’s code.
4. Wait a few seconds and press and release the same FOB
button (or 433MHz transmitter) as in step 3 a second time.
The 433MHz Receiver’s LED will blink green several times
indicating it is ending its learning procedure. When it is
ended, the 433MHz Receiver LED should resume blinking
red.
You can clear the 433MHz Receiver memory of all previously
learned transmitters.
1. Press the 433MHz Receiver’s programming button for
more than 8 seconds until the LED starts blinking green.
Release the programming button. The LED should now
be blinking red.
2. The 433MHz Receiver’s memory in now cleared. To learn
new transmitters, follow the steps for programming
transmitters into the 433MHz Receiver’s memory.
Programming Transmitter(s) Into 433MHz Receiver Memory
Deleting All Transmitters from 433MHz Receiver Memory
80-9357-1970-021 (09-06)
Page 2
433MHz Receiver
LED
Programming
Button
BR
O
WN/WHITE
WIRE
ORANGE
WIRE
RED
WIRE
BLA
CK
WIRE
1 2 3
2
1
3
4
2
1
3
4
White
Blac
k
Green
120VAC
Input
24VDC
Output
R
MP3000 Door Operator
RF Kit
Kit RFR1
Instructions -
A7872B
433MHz Receiver
RFR1
Power Supply
Terminal Strip
inside MP3000