F x 5 - s d t e c h n i c a l d ata F o r 6 0 h z
e l e c t r i c h e at e r s
C US
model
n
ote
v
oltage
n
ominal
W
attage
phase
m
ax.
m
otor
n
ameplate c
urrent
h
eater
W
attage
total
c
urrent
m
inimum circuit
a
mpacity
supply W
ire
m
aximum
Fuse
size
temperature
rise
c
ontactor
part
n
umber
(v) (kW)
(W)
(a)
(a)
(aWg)
(a)
°c
°F
FX5-SD-208160-030
208
3.0
1
2.7
2700
14.4
18.0
12
20
10.5
19.0
3619
FX5-SD-208160-050
208
5.0
1
2.7
4700
24.0
30.0
10
30
17.6
31.6
3619
FX5-SD-208160-075
208
7.5
1
2.7
7200
36.1
45.1
6
50
15.5
27.9
3619
FX5-SD-208160-100 * 208 10.0 1
2.7
9690
48.1
60.1
4
70
20.7
37.2
3619
FX5-SD-208360-030
208
3.0
3
1.4
2700
8.3
10.4
14
15
6.2
11.2
3619
FX5-SD-208360-050
208
5.0
3
1.4
4700
13.9
17.4
12
20
10.3
18.6
3619
FX5-SD-208360-075
208
7.5
3
1.4
7200
20.8
26.0
10
30
15.5
27.9
3619
FX5-SD-208360-100
208 10.0 3
1.4
9700
27.8
34.8
8
35
20.7
37.2
3619
FX5-SD-208360-150
208
15
3
1.4
14400 41.6
52.0
6
60
15.1
27.1
3619
FX5-SD-240160-030
240
3.0
1
2.7
2700
12.5
15.6
12
20
10.5
19.0
3619
FX5-SD-240160-050
240
5.0
1
2.7
4700
20.8
26.0
10
30
17.6
31.6
3619
FX5-SD-240160-075
240
7.5
1
2.7
7200
31.3
39.1
8
40
15.5
27.9
3619
FX5-SD-240160-100
240 10.0 1
2.7
9700
41.7
52.1
6
60
20.7
37.2
3619
FX5-SD-240160-150 * 240 15.0 1
1.4
14400 62.5
78.1
2
80
15.1
27.1
3619
FX5-SD-240360-030
240
3.0
3
1.4
2700
7.2
9.0
14
15
10.5
19.0
3619
FX5-SD-240360-050
240
5.0
3
1.4
4700
12.0
15.0
14
15
17.6
31.6
3619
FX5-SD-240360-075
240
7.5
3
1.4
7200
18.0
22.5
10
25
15.5
27.9
3619
FX5-SD-240360-100
240 10.0 3
1.4
9700
24.1
30.1
8
35
20.7
37.2
3619
FX5-SD-240360-150
240 15.0 3
1.4
14400 36.1
45.1
6
50
15.1
27.1
3619
FX5-SD-480160-030 ° 480
3.0
1
1.3
270
6.3
7.9
14
15
10.58 19.0
3619
FX5-SD-480160-050 ° 480
5.0
1
1.3
4700
10.4
13.0
14
15
17.6
31.6
3619
FX5-SD-480160-075 ° 480
7.5
1
1.3
7200
15.6
19.5
12
20
15.5
27.9
3619
FX5-SD-480160-100 ° 480 10.0 1
1.3
9100
20.8
26.0
10
30
20.7
37.2
3619
FX5-SD-480160-150 ° 480 15.0 1
1.3
14400 31.3
39.1
8
40
15.1
27.1
3619
FX5-SD-480160-200 ° 480 20.0 1
1.3
19400 41.7
52.1
6
60
20.1
36.1
3619
FX5-SD-480360-030
480
3.0
3
0.7
2700
3.6
4.5
14
15
10.5
19.0
3619
FX5-SD-480360-050
480
5.0
3
0.7
4700
6.0
7.5
14
15
17.6
31.6
3619
FX5-SD-480360-075
480
7.5
3
0.7
7200
9.0
11.3
14
15
15.5
27.9
3619
FX5-SD-480360-100
480 10.0 3
0.7
9700
12.0
15.0
14
15
20.7
37.2
3619
FX5-SD-480360-150
480 15.0 3
0.7
14400 18.0
22.5
10
25
15.1
27.1
3619
FX5-SD-480360-200
480 20.0 3
0.7
19400 24.1
30.1
8
35
20.1
36.1
3619
FX5-SD-480360-250
480 25.0 3
1.0
24200 30.1
37.6
8
40
12.2
22.0
3619
FX5-SD-480360-300
480 30.0 3
1.0
29200 36.1
45.1
6
50
14.6
26.4
3619
FX5-SD-480360-350
480 35.0 3
1.0
34200 42.1
52.6
6
60
17.1
30.7
3619
FX5-SD-600360-030
600
3.0
3
0.6
2700
2.9
3.6
14
15
10.5
19.0
3619
FX5-SD-600360-050
600
5.0
3
0.6
4700
4.8
6.0
14
15
17.6
31.6
3619
FX5-SD-600360-075
600
7.5
3
0.6
7200
7.2
9.0
14
15
15.5
27.9
3619
FX5-SD-600360-100
600 10.0 3
0.6
9700
9.6
12.0
14
15
20.7
18.1
3619
FX5-SD-600360-150
600 15.0 3
0.6
14400 14.4
18.0
12
20
15.1
27.1
3619
FX5-SD-600360-200
600 20.0 3
0.6
19400 19.2
24.0
10
25
20.1
36.1
3619
FX5-SD-600360-250
600 25.0 3
0.8
24200 24.1
30.1
8
35
25.1
45.2
3619
FX5-SD-600360-300
600 30.0 3
0.8
29200 28.9
36.1
8
40
14.6
26.4
3619
FX5-SD-600360-350
600 35.0 3
0.8
34200 33.7
42.1
8
45
17.1
30.7
3619
notes:
* Exceeds the 48 Amp Curcuit limit of NEC 424-22. DS5 not available for these units.
1. Minimum conductor size for 30˚C (86˚F) ambient. Derate conductor for ambient temperature. Use minimum 90˚C (194˚F) insulation.
2. Heater is functioning normally if at rated voltage the amp draw is within 10% of the value in this table.
3. Operation at lower voltages will result in reduced heat output and amp draw
4. Add "T" to model number when adding a built-in thermostat
5. Add "D" to model number when adding a built-in disconnect switch
6. Add "U" to model number for units with continuous fan option.
7. Add "A" to model number for units with stainless steel cabinet.