beautypg.com

Seal removal, Mechanical seal replacement – Viking Pump TSM630.3: N-RS Universal Seal User Manual

Page 7

background image

SECTION TSM 630.3

ISSUE

H

PAGE 7 OF 13

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

Failure to follow above listed

precautionary measures may result in

serious injury or death.

SEAL REMOVAL

DANGER !

Before starting pump, be sure all drive

equipment guards are in place.
Failure to properly mount guards may

result in serious injury or death.

10. Thread the bearing housing with lipseals, end cap,

outer bearing spacer collar and bearings installed into

bracket.

11. Put lockwasher and locknut on shaft. Insert length of

hardwood or brass through port opening between rotor

teeth to keep shaft from turning. Tighten locknut to 170-

190 ft.-lbs. torque. If tang does not line up with slot,

tighten locknut until it does. Failure to tighten locknut

or engage lockwasher tang could result in early bearing

failure and cause damage to rest of pump. Bend one tang

of the lockwasher into a slot on the locknut. Remove the

length of hardwood or brass from the port opening.

12. Adjust pump end clearance as in Thrust Bearing

Adjustment page 10.

13. Reinstall drain plug in casing. Lubricate all grease fittings

with multi-purpose grease, NLGI #2.

MECHANICAL SEAL

REPLACEMENT

This manual deals with the three standard types of mechanical

seals supplied on Universal Bracket models 4323A, 4324A,

4324AH, and 4327A.
1. Cartridge (Figure 6, page 8)
2.
Elastomeric O-ring (Figure 8, page 9)
3.
PTFE Wedge (Figure 9, page 9)

Identification of seal type is an important step towards

proper maintenance. For mechanical seal types not

shown, see the Seal Installation Drawing (SID) furnished