21. Attach to the brass or tin fast on tabs on the back side of the contactor.

Art # A-12353

22. Setup new contactor by inserting the main cables into the load side of the contactor. Cables may read W1 or

W2. Place them into the Load (L) side of the contactor. Orange into L1 Violet into L2 and Black into L3 of the

contactor.

23. Insert inverter harness 125x649-2 or 125x649-3 into the top port of the contactor and tighten.

Art # A-12352

CAUTION

Ensure that harness connections are tight and seated properly in the top terminal location.