37. Verify all connections and fittings are secure.
38. Verify there are no tools or pieces of sheet metal or other conductive objects left in the power supply or
touching any part inside.
Check for leaks
39. Reconnect the power once you have verified the last two steps and turn the system on.
40. If your coolant pump comes on, check for leaks and shut down immediately if you do until you can fix them.
If the pump does not come on for your model then check the operating sequence information in the operating
manual for your system to get the pump to circulate coolant.
41. Once you have determined there are no leaks, disconnect power and reinstall the side panels. Once the side
panels are back in place you can power up the unit and get back to cutting.
NOTE
Every effort has been made to provide complete and accurate information in this manual. However,
the publisher does not assume and hereby disclaims any liability to any party for any loss or damage
caused by errors or omissions in this Manual, whether such errors result from negligence, accident, or
any other cause.