Spare parts label, Torch parts selection – Tweco SL100 RPT User Manual
Page 3
June 6, 2003
3
Manual 0-2937
Connections with Adapter Kits
Leads with ATC Connectors
Connect the torch leads to the power supply per the in-
structions provided with the appropriate adapter kit.
WARNING
The shield connectors on the Adapter Leads should
be connected to the power supply in accordance
with instructions provided by the power supply
manufacturer. Use of a shielded torch on power
supplies not specifically designed for shielded leads
may result in damage to the power supply or im-
proper function.
Inspect the halves of the ATC Connector. Align the male
connector with the female receptacle and push them to-
gether by hand until they seat fully. Turn the Locking
Ring until it pulls the halves of the connector together
fully. Do not use tools to tighten the connector. If there
is any resistance to the ring turning, pull the halves of the
connector apart, realign the inner components, ensure that
the threaded components are aligned, and push the halves
of the connector together again.
A-03582
1
2
Control Cable
Connector (Machine
Torches Only)
ATC Male
Connector
ATC Adapter
Female Receptacle
Torch Leads
To
Power Supply
Leads with Standard (O2B) Connectors
Connect the torch leads to the power supply per the in-
structions provided with the appropriate adapter kit.
Spare Parts Label
The parts kit provided with this torch includes an adhe-
sive label. Select the small perforated section showing
the appropriate pressure setting for the amperage out-
put and leads length to be used with this torch. Refer to
the charts. Apply this section in the ‘Gas Supply’ area of
the label under the ‘Recommended operating pressure’
text. Discard any pressure setting sections of the label
that will not be used. Apply the large label to the power
supply, where the operator can see it for easy reference.
Torch Parts Selection
Refer to the Consumables Selection Chart for the vari-
ous torch parts for the application and operation.
WARNINGS
Disconnect primary power to the system before
disassembling the torch or torch leads.
DO NOT touch any internal torch parts while the
AC indicator light of the Power Supply is ON.
The shield cup (or shield cup body and end cap or de-
flector) holds the tip and starter cartridge in place. Put
one hand under the shield cup to catch the tip and starter
cartridge when the cup is removed.
Change the torch parts as follows:
1. Unscrew and remove the shield cup from the torch
head.
A-03598
Electrode
Starter Cartridge
Tip
Shield Cup
Assembly
Torch Head