07 duty cycle, Duty cycle -5, Firepower 125 at rated duty cycle – Tweco FP-165 Mini MIG Portable MIG Welder User Manual

Page 20: Firepower 135 at rated duty cycle, Firepower 165 at rated duty cycle

background image

INTRODUCTION

FIREpOwER Fp-125,135,165

Introduction

2-5

Manual 0-5123

2.07 Duty Cycle

Duty Cycle is the amount of arc-on time (actual welding time) during any 10 minute period that a machine can operate

at it’s rated output without damaging internal components. For example, the FirePower FP-135 is designed for 20%

duty cycle at 117 amps. This means that it has been designed and built to provide the rated amperage, 117 amps, for

2 minutes out of every 10 minute period. During the other 8 minutes of the 10 minute period, the FirePower FP-135

must idle and be allowed to cool. The thermal cutout will operate if the duty cycle is exceeded.
The FirePower FP-125 is designed for 19% duty cycle at 90 Amps.
The FirePower FP-135 is designed for 20% duty cycle at 117 Amps.
The FirePower FP-165 is designed for 18% duty cycle at 140 Amps.
If the unit overheats and the thermostat opens, wait 15 minutes for unit to cool.

FirePower 125 at Rated Duty Cycle

0

1

2

3

4

5

6

7

8

Minutes

9

10

Art # A-09058

Figure 2-5: Duty Cycle of FirePower125

FirePower 135 at Rated Duty Cycle

0

1

2

3

4

5

6

7

8

Minutes

9

10

Art # A-09059

Figure 2-6: Duty Cycle of FirePower135

FirePower 165 at Rated Duty Cycle

0

1

2

3

4

5

6

7

8

Minutes

9

10

Art # A-09060

Figure 2-7: Duty Cycle of FirePower165