TRANSTIG 300Pi

Manual 0-5309

3-11

INSTALLATION, OPERATION AND SETUP

LIFT TIG and HF TIG Programming Mode

Programming Parameter

Control Panel Display

Pre Flow

This parameter operates in 2T and

4T HF TIG mode only and is used to

provide gas to the weld zone prior to

striking the arc, once the torch trigger

switch has been pressed. This control

is used to dramatically reduce weld

porosity at the start of a weld.
Range is 0.0 to 5.0 seconds. Factory

default is 0.1 second.

(Pulse)

A-12103

Initial Current

This parameter operates in TIG modes

only and is used to set the start

current for TIG. In 4T mode the Initial

Current remains on until the torch

trigger switch is released after it has

been depressed. In 2T mode this is

the Initial Current for the Up Slope

current ramp.
Range is 5 to 315. Factory default is

30A.

(Pulse)

A-12104

Up Slope

This parameter operates in TIG modes

only and is used to set the time for the

weld current to ramp up from INITIAL

current to BASE current.
Range is 0.0 to 15.0 seconds. Factory

default is 1.0 second.

(Pulse)

A-12105